Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://bdtd.unifal-mg.edu.br:8443/handle/tede/2474
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFELIZARDO, Henrique Mateus Alves-
dc.creator.Latteshttp://lattes.cnpq.br/0430076312690120por
dc.contributor.advisor1ARAUJO, Hugo Gaêta-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1652639775122637por
dc.contributor.referee1ALMEIDA, Daniel Augusto de Faria-
dc.contributor.referee2TIRAPELLI, Camila-
dc.date.accessioned2024-11-14T17:41:27Z-
dc.date.issued2024-02-22-
dc.identifier.citationFELIZARDO, Henrique Mateus Alves. Efeito da miliamperagem em tomografia computadorizada de feixe cônico na avaliação de enxerto ósseo ao redor de implantes dentários. 2024. 54 f. Dissertação (Mestrado em Ciências Odontológicas) - Universidade Federal de Alfenas, Alfenas, MG, 2024.por
dc.identifier.urihttps://bdtd.unifal-mg.edu.br:8443/handle/tede/2474-
dc.description.resumoAs imagens de Tomografia Computadorizada de Feixe Cônico (TCFC) permitem a avaliação tridimensional do tecido ao redor dos implantes; entretanto, a distinção entre o tecido ósseo e materiais de enxerto pode ser prejudicada pela presença de artefatos de imagem causados pelos materiais de implantes, que têm alta densidade e número atômico. O ajuste dos parâmetros de exposição na TCFC pode reduzir o nível de exposição à radiação para o paciente e também influenciar na qualidade e ruído das imagens adquiridas. A alteração da miliamperagem (mA) está diretamente ligada à esses fatores e pode auxiliar na avaliação de imagens de TCFC com artefatos de imagem. O objetivo deste trabalho foi avaliar a influência da mA de TCFC na detecção da deiscência de enxerto ósseo adjacente à implantes dentários de titânio e zircônia. Vinte implantes de titânio e vinte de zircônia foram instalados em blocos de costela bovina. Foram criadas lacunas de no mínimo 2 mm entre os implantes e o osso e estas foram preenchidas com enxertos ósseos autógenos particulados. Em metade dos blocos a lacuna foi totalmente preenchida e na outra metade o material foi removido até a terceira espira do implante na face vestibular. Foram adquiridas imagens de TCFC com kilovoltagem 90kV, campo de visão 6x4, voxel de 0,133mm e miliamperagem 4, 6,3 e 10mA e avaliadas por 5 avaliadores para detecção da deiscência de enxerto ósseo. A área sob curva ROC, acurácia, sensibilidade e especificidade foram calculados e comparados entre os fatores de variação (material do implante e mA) pela análise de variância de dois fatores com nível de significância de 5%. Não houve diferenças estatisticamente significantes considerando os diferentes tipos de implantes e mA (p<0,05). Concluiu-se que um protocolo com menor exposição à radiação (i.e., menor mA) pode ser utilizado; entretanto, o uso da TCFC para avaliação da deiscência enxerto ósseo adjacente a diferentes tipos de implantes ainda é questionável e deve ser feito com cautela.por
dc.description.abstractCone Beam Computed Tomography (CBCT) images allow three-dimensional evaluation of tissue around implants; however, the distinction between bone tissue and graft materials may be compromised by image artifacts caused by implant materials, which have high density and atomic number. Adjusting exposure parameters in CBCT can reduce radiation exposure levels for the patient and also influence the quality and noise of the acquired images. The modification of milliamperage (mA) is directly related to these factors and can assist in the evaluation of CBCT images with image artifacts. This study aimed to evaluate the influence of CBCT’s mA on detecting bone graft dehiscence adjacent to titanium and zirconia dental implants. Twenty titanium and twenty zirconia implants were installed in bovine rib blocks. At least 2-mm gaps were created between the implants and the bone and filled with particulate autogenous bone grafts. In half of the blocks, the gap was filled entirely and in the other half, the grafting material was removed up to the third implant thread on the buccal side. CBCT images were acquired at kilovoltage (kV) 90kV, field of view 6x4cm, voxel size 0.133mm, and milliamperage 4, 6.3, and 10 mA and assessed by 5 observers to detect bone graft dehiscence. The area under the curve AUC, accuracy, sensitivity, and specificity were calculated and compared between the variation factors (dental implant material and mA) using a two-way analysis of variance with a significance level of 5%. There were no statistically significant differences considering the different types of implants and mA (p<0.05). In conclusion, a protocol with lower radiation exposure (i.e., lower mA) can be used; however, the use of CBCT for evaluating bone graft dehiscence adjacent to different types of implants is still questionable and should be approached with caution.eng
dc.description.provenanceSubmitted by Marlom César da Silva (marlom.silva@unifal-mg.edu.br) on 2024-11-14T17:40:42Z No. of bitstreams: 1 Dissertação de Henrique Mateus Alves Felizardo.pdf: 1761191 bytes, checksum: 5e69a51f47c5bcd97addca31aa99bf1e (MD5)eng
dc.description.provenanceApproved for entry into archive by Marlom César da Silva (marlom.silva@unifal-mg.edu.br) on 2024-11-14T17:40:57Z (GMT) No. of bitstreams: 1 Dissertação de Henrique Mateus Alves Felizardo.pdf: 1761191 bytes, checksum: 5e69a51f47c5bcd97addca31aa99bf1e (MD5)eng
dc.description.provenanceApproved for entry into archive by Marlom César da Silva (marlom.silva@unifal-mg.edu.br) on 2024-11-14T17:41:09Z (GMT) No. of bitstreams: 1 Dissertação de Henrique Mateus Alves Felizardo.pdf: 1761191 bytes, checksum: 5e69a51f47c5bcd97addca31aa99bf1e (MD5)eng
dc.description.provenanceMade available in DSpace on 2024-11-14T17:41:27Z (GMT). No. of bitstreams: 1 Dissertação de Henrique Mateus Alves Felizardo.pdf: 1761191 bytes, checksum: 5e69a51f47c5bcd97addca31aa99bf1e (MD5) Previous issue date: 2024-02-22eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal de Alfenaspor
dc.publisher.departmentFaculdade de Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIFAL-MGpor
dc.publisher.programPrograma de Pós-Graduação em Ciências Odontológicaspor
dc.rightsAcesso Abertopor
dc.subjectRadiologiapor
dc.subjectTomografia Computadorizada de Feixe Cônicopor
dc.subjectDiagnóstico por Imagempor
dc.subjectImplantes Dentáriospor
dc.subjectAutoenxertos.por
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleEfeito da miliamperagem em tomografia computadorizada de feixe cônico na avaliação de enxerto ósseo ao redor de implantes dentáriospor
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissertação de Henrique Mateus Alves Felizardo.pdf1,72 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.