Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://bdtd.unifal-mg.edu.br:8443/handle/tede/2262
Registro completo de metadados
Campo DCValorIdioma
dc.creatorPEREIRA, Silvio Romero Duarte-
dc.creator.Latteshttp://lattes.cnpq.br/4098670497818247por
dc.contributor.advisor1GONÇALVES, Flávio Aparecido-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7028472988716962por
dc.contributor.referee1LATUF, Marcelo de Oliveira-
dc.contributor.referee2TIEZZI, Rafael de Oliveira-
dc.date.accessioned2023-06-30T00:10:17Z-
dc.date.issued2023-01-30-
dc.identifier.citationPEREIRA, Silvio Romero Duarte. Análise do processo chuva-vazão utilizando hidrograma conceitual de Nash em bacias hidrográficas do Sul de Minas Gerais. 2023. 61 f. Dissertação (Mestrado em Ciência e Engenharia Ambiental) - Universidade Federal de Alfenas, Poços de Caldas, MG, 2023.por
dc.identifier.urihttps://bdtd.unifal-mg.edu.br:8443/handle/tede/2262-
dc.description.resumoTendo em vista que o crescimento populacional, o avanço da urbanização e a ação antrópica em ambientes naturais têm acarretado impactos ambientais de diferentes naturezas e que a impermeabilização desses espaços pode causar enchentes e a diminuição da qualidade das águas, faz-se cada vez mais necessária a quantificação dos efeitos gerados por esses processos. O hidrograma conceitual de Nash (1957) é um modelo de chuva-vazão que considera a bacia hidrográfica como um sistema linear que é função de dois parâmetros, sendo eles o número de reservatórios (n) e a taxa de decaimento (k). Como forma de avaliar as diferenças e comparar duas situações distintas, os valores desses parâmetros foram calculados para eventos de duas estações diferentes, a estação Itajubá, no rio Sapucaí, e a estação PCH Ninho da Águia Montante, localizada no rio Santo Antônio. Essas estações estão localizadas em Municípios vizinhos, sendo que o rio Santo Antônio é afluente do Sapucaí. Para a separação do escoamento foi utilizado o método de separação gráfica. Da totalidade dos eventos estudados, três foram descartados pelo fato de apresentarem resultados anormais para o estudo, sendo que a justificativa é que exista alguma perturbação na vazão medida que ocasionou esse problema. Os valores médios de n e k para a estação Itajubá foram de 8,63 e 15,81, respectivamente, enquanto para a estação PCH Ninho da Águia Montante esses mesmos valores foram 4,13 e 10,03. A média dos valores de R² foram de 0,48 e 0,51, respectivamente, sendo considerado aceitável. Houve boa correlação entre os parâmetros n e k para as duas estações, sendo maior na de Itajubá. No que tange ao tempo de pico (tp), houve maior correlação deste com o parâmetro n na estação Itajubá, enquanto ocorreu o contrário quando se analisou a correlação entre a vazão de pico (Qp) e o parâmetro k. Os dados obtidos mostraram que a modelagem se mostrou eficiente e a aplicabilidade do modelo foi satisfatória.por
dc.description.abstractBearing in mind that population growth, the advance of urbanization and anthropic action in natural environments have led to environmental impacts of different natures and that the waterproofing of these spaces can cause floods and decrease the quality of water, it is increasingly necessary the quantification of the effects generated by these processes. Nash's conceptual hydrograph (1957) is a rainfall-runoff model that considers the watershed as a linear system that is a function of two parameters, namely the number of reservoirs (n) and the rate of decay (k). As a way of evaluating the differences and comparing two different situations, the values of these parameters were calculated for events at two different stations, the Itajubá station on the Sapucaí river and the PCH Ninho da Águia Montante station, located on the Santo Antônio river. These stations are located in neighboring municipalities, and the Santo Antônio river is a tributary of the Sapucaí. For the flow separation, the graphic separation method was used. Of all the events studied, three were discarded due to the fact that they presented abnormal results for the study, and the justification is that there is some disturbance in the measured flow that caused this problem. The average values of n and k for the Itajubá station were 8.63 and 15.81, respectively, while for the PCH Ninho da Águia Montante station these same values were 4.13 and 10.03. The average values of R² were 0.48 and 0.51, respectively, being considered acceptable. There was a good correlation between the n and k parameters for the two stations, being higher in Itajubá. With regard to the peak time (tp), there was a greater correlation between this and the n parameter at the Itajubá station, while the opposite occurred when the correlation between the peak flow (Qp) and the k parameter was analyzed. The data obtained showed that the modeling was efficient and the applicability of the model was satisfactory.eng
dc.description.provenanceSubmitted by Thaís Aparecida de Lima (thais.aplima@unifal-mg.edu.br) on 2023-06-30T00:08:37Z No. of bitstreams: 2 Dissertacao_SilvioRomeroDuartePereira_2023_PPGCEA.pdf: 2054601 bytes, checksum: 41d5755e6acda74340992cbdfbad2bca (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceApproved for entry into archive by Thaís Aparecida de Lima (thais.aplima@unifal-mg.edu.br) on 2023-06-30T00:09:52Z (GMT) No. of bitstreams: 2 Dissertacao_SilvioRomeroDuartePereira_2023_PPGCEA.pdf: 2054601 bytes, checksum: 41d5755e6acda74340992cbdfbad2bca (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceApproved for entry into archive by Thaís Aparecida de Lima (thais.aplima@unifal-mg.edu.br) on 2023-06-30T00:10:07Z (GMT) No. of bitstreams: 2 Dissertacao_SilvioRomeroDuartePereira_2023_PPGCEA.pdf: 2054601 bytes, checksum: 41d5755e6acda74340992cbdfbad2bca (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceMade available in DSpace on 2023-06-30T00:10:17Z (GMT). No. of bitstreams: 2 Dissertacao_SilvioRomeroDuartePereira_2023_PPGCEA.pdf: 2054601 bytes, checksum: 41d5755e6acda74340992cbdfbad2bca (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2023-01-30eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal de Alfenaspor
dc.publisher.departmentInstituto de Ciência e Tecnologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIFAL-MGpor
dc.publisher.programPrograma de Pós-Graduação em Ciência e Engenharia Ambientalpor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectModelos hidrológicos.por
dc.subjectEscoamento superficial.por
dc.subjectHidrologia urbana.por
dc.subject.cnpqENGENHARIA SANITARIA::RECURSOS HIDRICOSpor
dc.titleAnálise do processo chuva-vazão utilizando hidrograma conceitual de Nash em bacias hidrográficas do Sul de Minas Geraispor
dc.title.alternativeAnalysis of the rainfall-runoff process using Nash’s conceptual hydrograph in watersheds in the south of Minas Geraiseng
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissertacao_SilvioRomeroDuartePereira_2023_PPGCEA.pdf2,01 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Este item está licenciada sob uma Licença Creative Commons Creative Commons