Título: Tratamento de água residuária proveniente do processo de lavagem de tecidos utilizando reator UASB
Título(s) alternativo(s): Treatment of wastewater from the laundry washing process using UASB reactor
Autor: PIZZO, Matheus Marques 
Primeiro orientador: SANCINETTI, Giselle Patrícia
Primeiro coorientador: PIRES, Lorena Oliveira
Primeiro membro da banca: BRAGA, Juliana Kawanishi
Segundo membro da banca: GIRALDI, Tânia Regina
Resumo: A falta de água com qualidade é um tema que chama a atenção de todos. À medida que os anos passam, leis e normas tornam-se cada vez mais rigorosas quanto a qualidade das águas descartadas no meio ambiente. Dentre as águas residuárias em questão, destacam-se os efluentes de lavanderias, visto que geram altos volumes de resíduos líquidos, caracterizados com altas quantidades de matéria orgânica e surfactantes. Por apresentarem estruturas complexas, os surfactantes apresentam baixa biodegradabilidade, tornando difícil seu tratamento. Comumente é utilizado o método físico-químico para tratamento. Visando uma alternativa mais sustentável, o presente trabalho teve como objetivo o tratamento de águas residuárias provenientes do processo de lavagem de tecido utilizando o Reator Anaeróbio de Fluxo Ascendente e Manta de Lodo, também conhecido por UASB (Upflow Anaerobic Sludge Blanket). O inóculo utilizado foi proveniente de abatedouro de aves, DACAR. O reator foi alimentado com água residuária de lavanderia (ARL), coletada em uma lavanderia comercial local e diluída em meio nutricional. O tempo de detenção hidráulica foi 48 horas, com vazão de 94 mL/h. O tempo total de operação do reator foi 317 dias. Foram realizadas análises físico-químicas para demanda química de oxigênio, surfactantes aniônicos, alcalinidade total, ácidos totais, pH e sólidos totais para controle e monitoramento do reator. Foram ainda realizados ensaios hidrodinâmicos e de produção de biogás. Os resultados hidrodinâmicos apontaram TDH (tempo de detenção hidráulica) experimental próximo ao teórico, além de identificar o regime de escoamento como pistonado. Ao todo foram realizadas sete fases de operação, alterando as concentrações de DQO e LAS (linear alquilbenzeno sulfonado) presentes de acordo com a eficiência de remoção de DQO e LAS (aproximadamente 600 a 1000 mg DQO/L e 2 a 10mg LAS/L). As eficiências de remoção variaram de 85,83% a 95,46% para DQO e de 35% a 64% para surfactante. Quanto a produção de biogás, foi encontrado um valor de 16,32 ± 0,81 cm³/h. Desta forma, pode-se concluir que o reator apresentou um bom desempenho no tratamento de ARL segundo as condições propostas.
Abstract: The lack of quality in water is a theme that draws everyone's attention. As the years pass, laws and regulations become increasingly stringent as to the quality of the water discarded in the environment. Among the wastewater in question, the laundry effluents stand out, since they generate high volumes of liquid waste, characterized by high amounts of organic matter and surfactants. Because they have complex structures, the surfactants present low biodegradability, making their treatment difficult. The physico-chemical method for treatment is commonly used. Aiming for a more sustainable alternative, the present work had as objective the treatment of wastewater from the fabric washing process using the Upflow Anaerobic Reactor and Sludge Blanket, UASB. The inoculum used was from poultry slaughterhouse, DACAR. The reactor was fed with laundry wastewater (LW), collected at a local commercial laundry and diluted in a nutritional solution. The hydraulic detention time used was 48 hours, with a flow rate of 94 mL / h. The total time of reactor operation was 317 days. Physical and chemical analyzes were performed for chemical oxygen demand, anionic surfactants, total alkalinity, total acids, pH and total solids for control and monitoring of the reactor. Hydrodynamic trials and biogas production were also carried out. The hydrodynamic results showed experimental HRT (hydraulic retention time) close to the theoretical, besides identifying the flow regime as plug flow. Seven phases of operation were performed, changing the concentrations of the substrates present in accordance with the removal efficiency of COD and LAS (linear alkylbenzene sulfonate) (approximately 600 to 1000 mg COD/L and 2 to 10mg LAS/L). The removal efficiencies ranged from 85.83% to 95.46% for COD and from 35% to 64% for LAS. As for biogas production, a value of 16.32 ± 0.81 cm³ / h was found. In this way, it can be concluded that the reactor performed well in the treatment of LW according to the proposed conditions.
Palavras-chave: Águas residuais - purificação.
Agentes ativos de superfícies.
Digestão anaeróbia.
Modelos hidrodinâmicos.
Área(s) do CNPq: ENGENHARIAS::ENGENHARIA SANITARIA
Idioma: por
País: Brasil
Instituição: Universidade Federal de Alfenas
Sigla da instituição: UNIFAL-MG
Departamento: Instituto de Ciência e Tecnologia
Programa: Programa de Pós-Graduação em Ciência e Engenharia Ambiental
Citação: PIZZO, Matheus Marques. Tratamento de água residuária proveniente do processo de lavagem de tecidos utilizando reator UASB. 2019. 85 f. Dissertação (Mestrado em Ciência e Engenharia Ambiental) - Universidade Federal de Alfenas, Poços de Caldas, 2019.
Tipo de acesso: Acesso Aberto
Endereço da licença: http://creativecommons.org/licenses/by-nc-nd/4.0/
URI: https://bdtd.unifal-mg.edu.br:8443/handle/tede/1508
Data de defesa: 28-Fev-2019