Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://bdtd.unifal-mg.edu.br:8443/handle/tede/1229
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBENTO, Gabriela-
dc.creator.Latteshttp://lattes.cnpq.br/3294939490318150por
dc.contributor.advisor1HADDAD, Marcela Filié-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8789756733399169por
dc.contributor.advisor-co1VERRI, Fellippo Ramos-
dc.contributor.referee1ALMEIDA, Daniel Augusto de Faria-
dc.contributor.referee2PESQUEIRA, Aldieris Alves-
dc.date.accessioned2018-10-09T20:27:12Z-
dc.date.issued2018-07-27-
dc.identifier.citationBENTO, Gabriela. Análise biomecânica de implantes cone morse estreitos x convencionais para reabilitações unitárias anteriores - estudo pelo método dos elementos finitos. 2018. 39 f. Dissertação (Mestrado em Ciências Odontológicas) - Universidade Federal de Alfenas, Alfenas, MG, 2018.por
dc.identifier.urihttps://bdtd.unifal-mg.edu.br:8443/handle/tede/1229-
dc.description.resumoA reabilitação anterior da maxila representa um desafio para a implantodontia devido a pouca espessura óssea. Para contornar este problema, a indústria lança implantes de pequeno diâmetro.Porém, ainda há dúvidas sobre o comportamento biomecânico deste tipo de implante. Assim, este estudo teve como objetivo analisar, pelo Método dos Elementos Finitos (MEF), o comportamento biomecânico de implantes nesta região comparando diâmetro convencional (3.75 mm) e implantes estreitos (3.5 e 2.9 mm). Foram simulados 3 modelos tridimensionais representando blocos de osso da região maxilar anterior direita, com um implante na região do incisivo lateral, sempre de 13 mm de comprimento, nos diâmetros citados acima. Sobre os implantes, foi simulada coroa totalmente cerâmica cimentada. A análise pelo método dos elementos finitos foi realizada no software ANSYS utilizando cargas de 178N aplicadas com inclinação de 0, 30 e 60 graus em relação ao longo eixo dos implantes. A análise dos mapas de tensões de von Mises mostrou que houve maiores concentrações de tensões localizadas na região do intermediário, independente da direção da força, aumentando conforme o aumento do ângulo de aplicação de força, e se dissipando ao longo das roscas dos implantes. Houve um ligeiro aumento nas tensões para os implantes de 2.9 mm quando comparado aos demais. Os implantes de maior diâmetro apresentaram maiores áreas de concentrações de tensões na região do intermediário e ao longo das roscas até a região apical quando comparado aos modelos de 2.9 mm. O mesmo ocorreu para a análise de tensão máxima principal nos carregamentos de 30 e 60 graus, principalmente sob tensões de tração. Para o carregamento de 0 grau não foi possível observar influência do diâmetro dos implantes nas concentrações de tensões na região do tecido ósseo. Dentro das limitações do estudo foi possível concluir que em todos os modelos as maiores tensões concentraram na região do intermediário e primeiras roscas do implante, sendo maior à medida que aumentou a inclinação da força ou se diminuiu o diâmetro do implante. Apesar disso, o implante de 2.9mm de diâmetro apresentou o melhor comportamento biomecânico diante de tecido ósseo estreito. Repor incisivos laterais com implantes mais estreitos, onde forças oclusais leves estão presentes é uma opção de tratamento viável.por
dc.description.abstractAnterior rehabilitation of the maxilla represents a challenge for implant dentistry due to poor bone thickness. To solve this problem, the industry launches narrow diameter implants. However, there are still doubts about the biomechanical behavior of this type of implant. Thus, the aim of this study was to analyze the biomechanical behavior of implants in this region by comparing conventional diameter (3.75 mm) and narrow implants (3.5 and 2.9 mm) using the Finite Element Method (FEM). Three 3-dimensional models were simulated representing bone blocks of the right anterior maxillary region, with an implant in the lateral incisor region, always 13 mm lenght, in the diameters mentioned above. On implants, it was simulated crown fully cemented ceramics. Finite element analysis was performed using ANSYS software using loads of 178N applied with 0, 30 and 60 degree inclination in relation to the long axis of the implants. Analysis of the von Mises stress maps showed that there were higher stress concentrations located in the intermediate region, regardless of force direction, increasing as the force application angle increased, and dissipating along the implant threads. There was a slight increase in stresses for the 2.9 mm implants when compared to the others. The larger diameter implants presented higher areas of stress concentrations in the intermediate region and along the threads to the apical region when compared to the 2.9 mm models. The same was true for the analysis of maximum principal stress in 30 and 60 degree loads, especially under tensile stresses. For loading of 0 degrees it was not possible to observe influence of the diameter of the implants in the concentrations of stresses in the region of the bone tissue. Within the limitations of the study, it was possible to conclude that in all models, the higher stresses were concentrated in the intermediate region and first threads of the implant, being larger as the force inclination increased or the implant diameter decreased. Despite this, the 2.9mm diameter implant presented the best biomechanical behavior in front of narrow bone tissue. Replace lateral incisors with narrow diameter implants where low oclusal stress are present represents a good option for treatment.eng
dc.description.provenanceSubmitted by Marlom César da Silva (marlom.silva@unifal-mg.edu.br) on 2018-10-09T20:26:25Z No. of bitstreams: 2 Diseertação Gabriela Bento.pdf: 1231155 bytes, checksum: 0e20b82f48cb88460d5b03755e8afe86 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceApproved for entry into archive by Marlom César da Silva (marlom.silva@unifal-mg.edu.br) on 2018-10-09T20:26:41Z (GMT) No. of bitstreams: 2 Diseertação Gabriela Bento.pdf: 1231155 bytes, checksum: 0e20b82f48cb88460d5b03755e8afe86 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceApproved for entry into archive by Marlom César da Silva (marlom.silva@unifal-mg.edu.br) on 2018-10-09T20:26:57Z (GMT) No. of bitstreams: 2 Diseertação Gabriela Bento.pdf: 1231155 bytes, checksum: 0e20b82f48cb88460d5b03755e8afe86 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceMade available in DSpace on 2018-10-09T20:27:12Z (GMT). No. of bitstreams: 2 Diseertação Gabriela Bento.pdf: 1231155 bytes, checksum: 0e20b82f48cb88460d5b03755e8afe86 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-27eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal de Alfenaspor
dc.publisher.departmentFaculdade de Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIFAL-MGpor
dc.publisher.programPrograma de Pós-Graduação em Ciências Odontológicaspor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectImplantes Dentáriospor
dc.subjectPrótese Dentária fixada por Implantepor
dc.subjectPrótese e Implantespor
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAnálise biomecânica de implantes cone morse estreitos x convencionais para reabilitações unitárias anteriores - estudo pelo método dos elementos finitospor
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Diseertação Gabriela Bento.pdf1,2 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Este item está licenciada sob uma Licença Creative Commons Creative Commons